About the article
I.P. Popov
There are oscillators with mutual conversion of the kinetic energy of the load into the energy of either a magnetic or electric field, as well as oscillators with mutual conversion of the potential energy of the spring into the energy of either an electric or magnetic field. The aim of the work was to build a mathematical model of three inductive oscillators. In the LLL of the oscillator, free current fluctuations occur (without external power supply), therefore, any phase is a source of reactive power of the other two phases. This circumstance creates prerequisites for reducing the flow of reactive power in the network due to mutual compensation of the reactive power of the phases. In other words, the phases of a symmetrical load can at least partially exchange reactive power among themselves, and not with the network.
oscillator, energy, tri-inductive, oscillations, reactive power, phase.