About the article

ANALYTICAL FEATURES OF STUDY OF FOAM STABILITY

DOI: 10.46573/2658-7459-2024-3-89-94

Download article

Authors

G.A. Tumanov, A.V. Starovoitov, E.I. Laguseva, K.V. Chalov, A.I. Pichugina, V.Yu. Doluda

Abstract

The article considers the possibility of determining the foam resistance of foam-forming solutions in laboratory conditions in order to bring the results obtained in accordance with the data established by GOST R 50588-93. The time of settling of half of the foam column was measured using an installation consisting of a cylinder with a lower air supply and a stopwatch. A portion of the blowing agent was introduced into the measuring cylinder, after which air was blown until a stable foam column was formed. Increasing the processing time of the foaming solution up to 5 min contributed to the increase of the foam settling time up to 460 s. On further increasing the blowing agent treatment time with air up to 10 min, a shift in the maximum settling time of 50 % of the foam column was observed up to an air flow rate of 150 ml/min. The optimum treatment time of the foaming solution was 10 min at an air flow rate of 150 ml/min. It is concluded that at the volume of the foaming agent from 30 to 60 ml the obtained values of the settling time of 50 % of the foam column fall within the range of values given in GOST R 50588-93.

Keywords

stability, foam, foam settling time, stability, foam settling velocity.