About the article
A.V. Gavrilenko, T.R. Barkaya, U.V. Sizov, E.V. Rocheva
In this paper there is description of a metal-wood panel with thin flat steel walls stiffened by timber ribs. It is noted that production ease of proposed panel is its advantage whereas difficulties areconnected with choosing of optimal ribs spacing and implementation of a tight joint of the walls to timber elements of flanges. Description of specimens, materials characteristics and test method are given. Four specimens were tested. Two of them were hollow and other two had extruded polystyrene foam filling in its cavity. Bearing capacity and load-deflection behavior were revealed during the bending test. Conclusion is made that beams perform well under load. Further improving of the proposed construction could be achieved by choosing of optimal stiffening ribs spacing and tightening of contact between top part of the walls and timber elements of the upper flange.
metal-wood panel, flexible wall, bending test.